Paper Reading AI Learner

Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR Classification

2026-11-05 12:47:38
Dang-Khoa Bui, Quang-Huy Tran, Minh-Khoi Nguyen-Bui, Duc-Tuan Ngo, Thanh-Trong Tran, Tuan-Khoi Nguyen, Hoang-Anh Ngo

Abstract

Benchmarks of class-imbalance strategies for multimodal chest X-ray (CXR) and electronic health record (EHR) prediction are often evaluated on record-level splits of cohorts in which one patient contributes several radiographs. We audit such a benchmark on 29,083 MIMIC-CXR radiographs of 10,479 patients with eight diagnosis targets. First, the record-split benchmark was misleading: a lookup table that copies the label of a development-set radiograph with the same EHR vector nearly matched the best model, and on unseen patients every model fell to the level of predicting every case positive. Second, tracing the labels back to MIMIC-IV explained why: each patient's labels are keyword matches on the diagnosis codes of a single admission, copied, with one EHR vector per patient, to all of the patient's radiographs, so about a third of the radiographs carry labels that differ from the codes of their own admission. Third, under patient-separated evaluation with admission-aligned and rule-refined labels, the initial conclusions do not hold: in the evaluated configurations no imbalance strategy raised the observed mean macro F2 over no augmentation by more than 0.01, tuned tree ensembles showed no consistent advantage over tuned logistic regression, and the released EHR variables stayed at the level of the all-positive baseline, whereas the diagnostic history available at imaging time and image embeddings exceeded it, including, with rule-refined labels, a CheXpert-trained encoder that never saw these radiographs; RAD-DINO had seen 96.6% of them during self-supervised pretraining. Adding either encoder to the diagnostic history gave no statistically significant F2 gain; exploratory AUROC gains were significant with RAD-DINO but not with DenseNet. We provide reusable diagnostics, a leakage-aware protocol and a checklist.

Abstract (translated)

URL

https://arxiv.org/abs/2611.07950

PDF

https://arxiv.org/pdf/2611.07950.pdf


Tags
3D Action Action_Localization Action_Recognition Activity Adversarial Agent Attention Autonomous Bert Boundary_Detection Caption Chat Classification CNN Compressive_Sensing Contour Contrastive_Learning Deep_Learning Denoising Detection Dialog Diffusion Drone Dynamic_Memory_Network Edge_Detection Embedding Embodied Emotion Enhancement Face Face_Detection Face_Recognition Facial_Landmark Few-Shot Gait_Recognition GAN Gaze_Estimation Gesture Gradient_Descent Handwriting Human_Parsing Image_Caption Image_Classification Image_Compression Image_Enhancement Image_Generation Image_Matting Image_Retrieval Inference Inpainting Intelligent_Chip Knowledge Knowledge_Graph Language_Model LLM Matching Medical Memory_Networks Multi_Modal Multi_Task NAS NMT Object_Detection Object_Tracking OCR Ontology Optical_Character Optical_Flow Optimization Person_Re-identification Point_Cloud Portrait_Generation Pose Pose_Estimation Prediction QA Quantitative Quantitative_Finance Quantization Re-identification Recognition Recommendation Reconstruction Regularization Reinforcement_Learning Relation Relation_Extraction Represenation Represenation_Learning Restoration Review RNN Robot Salient Scene_Classification Scene_Generation Scene_Parsing Scene_Text Segmentation Self-Supervised Semantic_Instance_Segmentation Semantic_Segmentation Semi_Global Semi_Supervised Sence_graph Sentiment Sentiment_Classification Sketch SLAM Sparse Speech Speech_Recognition Style_Transfer Summarization Super_Resolution Surveillance Survey Text_Classification Text_Generation Time_Series Tracking Transfer_Learning Transformer Unsupervised Video_Caption Video_Classification Video_Indexing Video_Prediction Video_Retrieval Visual_Relation VQA Weakly_Supervised Zero-Shot