Paper Reading AI Learner

End-to-end prostate lesion segmentation and detection from undersampled diffusion-weighted MRI

2026-10-24 09:13:57
Lukas T. Rotkopf, Marco Schlimbach, Kevin Kr\"{o}ninger, Stefan O. Schoenberg, Heinz-Peter Schlemmer, Jens Kleesiek, Moritz Rempe

Abstract

Automated prostate lesion detection from diffusion-weighted MR imaging (DWI) conventionally relies on reconstructed images and does not fully use all acquisition information. We present an end-to-end network that uses complex multicoil DWI data and coil sensitivity information for prostate lesion segmentation. We included 269 fastMRI prostate examinations with additional voxel-level lesion annotations. Of these, 64 examinations contained PIRADS 4 or 5 lesions. The proposed network, VarNet-Seg, consists of a k-space variational network (VarNet) with six variational cascades and an image-space 3D segmentation U-Net. Comparator models used the same segmentation architecture with fully coil-combined images (CC-Seg), fixed root-sum-of-squares reconstruction (RSS-Seg), or fixed SENSE reconstruction (SENSE-Seg). We performed ablations with end-to-end training and data consistency (DC) enabled or disabled. We evaluated lesion segmentation using Dice and patient-level detection using AUROC in five-fold cross-validation with full sampling, simulated undersampling, added noise, or both. VarNet-Seg achieved the highest Dice at every undersampling level. At eight-fold acceleration, Dice was 0.22 for VarNet-Seg, 0.14 for SENSE-Seg and 0.16 for VarNet-Seg (no DC). The paired difference from SENSE-Seg was 0.08 (95% CI, 0.04-0.11). With full sampling, VarNet-Seg and RSS-Seg performed similarly (0.40 vs 0.39). Patient-level AUROC decreased from 0.75 with full sampling to 0.63 at eight-fold acceleration; corresponding RSS-Seg AUROCs were 0.76 and 0.64. The proposed multicoil network improved prostate lesion segmentation under simulated undersampling compared to conventional models. Matched ablations supported contributions from both end-to-end training and data consistency. Prospective evaluation is needed to establish whether this approach can be used clinically in accelerated prostate DWI.

Abstract (translated)

URL

https://arxiv.org/abs/2610.33554

PDF

https://arxiv.org/pdf/2610.33554.pdf


Tags
3D Action Action_Localization Action_Recognition Activity Adversarial Agent Attention Autonomous Bert Boundary_Detection Caption Chat Classification CNN Compressive_Sensing Contour Contrastive_Learning Deep_Learning Denoising Detection Dialog Diffusion Drone Dynamic_Memory_Network Edge_Detection Embedding Embodied Emotion Enhancement Face Face_Detection Face_Recognition Facial_Landmark Few-Shot Gait_Recognition GAN Gaze_Estimation Gesture Gradient_Descent Handwriting Human_Parsing Image_Caption Image_Classification Image_Compression Image_Enhancement Image_Generation Image_Matting Image_Retrieval Inference Inpainting Intelligent_Chip Knowledge Knowledge_Graph Language_Model LLM Matching Medical Memory_Networks Multi_Modal Multi_Task NAS NMT Object_Detection Object_Tracking OCR Ontology Optical_Character Optical_Flow Optimization Person_Re-identification Point_Cloud Portrait_Generation Pose Pose_Estimation Prediction QA Quantitative Quantitative_Finance Quantization Re-identification Recognition Recommendation Reconstruction Regularization Reinforcement_Learning Relation Relation_Extraction Represenation Represenation_Learning Restoration Review RNN Robot Salient Scene_Classification Scene_Generation Scene_Parsing Scene_Text Segmentation Self-Supervised Semantic_Instance_Segmentation Semantic_Segmentation Semi_Global Semi_Supervised Sence_graph Sentiment Sentiment_Classification Sketch SLAM Sparse Speech Speech_Recognition Style_Transfer Summarization Super_Resolution Surveillance Survey Text_Classification Text_Generation Time_Series Tracking Transfer_Learning Transformer Unsupervised Video_Caption Video_Classification Video_Indexing Video_Prediction Video_Retrieval Visual_Relation VQA Weakly_Supervised Zero-Shot